Acoustic Panel NRC & Performance Guide
Acoustic performance values such as NRC, absorption coefficients, or similar ratings should only be used when they are supported by a current test report for the exact panel construction and tested mounting assembly.
Why installation changes acoustic performance
Results can vary based on panel construction, backing/felt, air space, substrate, insulation, mounting method, and test standard. A panel tested over an air cavity or absorptive backing should not automatically be represented by the same value when installed directly to another substrate.
What to request for a specification
- Exact product/model identification
- Test standard and report number
- Tested panel construction
- Mounting method and cavity depth
- Backing or insulation used in the test assembly
- Reported NRC or absorption data
- Current validity and product mapping
Do not transfer ratings between products
Visually similar slat panels can use different cores, veneers, felt, spacing, dimensions, or mounting assemblies. A rating from another product, supplier, or historical configuration should not be assumed to apply.
Fire and other classifications
Fire or reaction-to-fire claims require separate, current documentation for the exact product and configuration. Acoustic performance documentation does not establish fire classification.
For project documentation, visit Acoustic Wall Panel Technical Resources or the Architect & Specifier Center.